| The
CT-DH-4 is installed for cooling
and dehumidifying control. This
unit may be used independently
or with many other Green Air Products
controls to create an integrated
system. This diagram shows how
to install the CT-DH-4 for independent
control of exhaust fans for cooling
and a dehumidifier for removing
unwanted humidity while synchronizing
ventilation with CO2 enrichment.
When the temperature exceeds the
dial set points, the CT-DH-4 initiates
a venting cycle and CO2 generation
is temporarily defeated. The Cyclestat-4
is used to time the frequency
and duration of the CO2 production.
In the event of an exhaust cycle
the Cyclestat will reset and immediately
replenish CO2 enrichment upon
completion of the exhaust function.
The Cyclestat-4 timer has a built
in photo sensor that prevents
CO2 operation during darkness
periods. If you are using a CO2
timer that does not have a photosensor
you can get that option built
into as a CT-DH-4P. |
| The
CO2 generator or emitter system
is plugged into the Cyclestat
and the Cyclestat is plugged into
the bottom left CO2 outlet of
the CT-DH-4. The dehumidifier
is plugged into the top left "dehumidify"
outlet. The exhaust fans are plugged
into the right outlets. |